The upside-down roof concept is as simple to use as it is effective. As you see in the following pictures. The efficiency of the upside-down roof concept has been proved by extensive tests and practical application over long years in Europe, Canada, USA and the Middle East.
Extruded Polystyrene panels can be worked with conventional wood working tools. The panels could be bound together with hot bitumen, dispersion-type structural or special adhesives. Instruction for use and safety precautions relating to the adhesive must be observed.
Ensure the concrete slab is clean and fairy smoother, then membrane can laid directly on the slab. If the concrete surface cannot be made smooth, it is required to lay directly on the slab. If the concrete surface cannot be made smooth, it is required to lay a protection sheet below the membrane.
Protection layer against the wind uplift, buoyancy and ultraviolet degradation can either be of gravel or paving slabs. When using pebble gravel it is necessary to use the round, washed type having a 15-30mm size distribution, laid dry on a synthetic, on fabric, rot proof felt filtering layer.
With the normal gravel-topped specification, water percolates down through the gravel over and between the insulation boards, until it reaches the water proofing membrane where it then drains off to the roof outlets. On Terrance decks, water will drain from the top surface of the terrace and Extruded Polystyrene Board and from the roof membrane.
The draining outlet should, therefore have a connection at the membrane level and at the top terrace and Extruded Polystyrene Board top surface levels. The roof slab should be sloped towards the drainage outlet. Waterproofing membrane should be properly installed around the drainage openings so that water drains off the waterproofing membrane to the roof outlet.